Lightning rod installed on the ridge line. Lightning rod installed in the gutter zone near the snow stopping line. Aluminum lightning rod with grounding line. 5.3 – Solar panel support systems – 4. Protection against lightning and surges in photovoltaic systems 337 5.3. 4. PROTECTION AGAINST LIGHTNING AND SURGES IN PHOTOVOLTAIC SYSTEMS The lightning protection system can be connected directly to the standing seam cladding with spot clamps, without holes and interruption of the continuity of the cladding. For the construction of the collection network and for the connection of the photovoltaic panels, the use of materials and accessories compatible with the titanium-zinc zintek® cladding (such as galvanized steel, stainless steel, aluminum) is recommended. The use of materials such as copper and its alloys is not allowed. EXCERPT