SUBSTRUCTURE TYPES
- WOOD-METAL
- METAL
1. zintek® stepped slats roof cladding
2. zintek® ducts
3a. Acoustic insulation draining filament mat h. 8 mm
4a. Folded sheet metal support on battens, ventilated gap
5. Breathable waterproof sheathing
6. Thermal-acoustic insulation layer
7a. Vapour barrier to be verified with special thermo-hygrometric evaluations
1. zintek® stepped slats roof cladding
2. zintek® ducts
3a. Acoustic insulation draining filament mat h. 8 mm
4b. Folded sheet metal support on omega metal profiles, ventilated gap
5. Breathable waterproof sheathing
6. Thermal-acoustic insulation layer
7a. Vapour barrier to be verified with special thermo-hygrometric evaluations
EXAMPLES OF INSTALLATION SCHEMES
![](https://www.zintek.it/wp-content/uploads/2020/01/applicazioni-zintek-doghe-giunto-singolo.jpg)
SINGLE JOINT
![](https://www.zintek.it/wp-content/uploads/2020/01/applicazioni-zintek-doghe-giunto-ridotto.jpg)
REDUCED JOINT
![](https://www.zintek.it/wp-content/uploads/2020/01/applicazioni-zintek-doghe-giunto-doppio.jpg)
DOUBLE JOINT
TYPES OF FASTENING SYSTEMS
![](https://www.zintek.it/wp-content/uploads/2020/01/applicazioni-zintek-doghe-tipologia-fissaggio.jpg)
1. ventilated gap
2. COUPLING
3. FASTENING
TECHNICAL SPECIFICATIONS
USE
Roof cladding and coating
SUBSTRUCTURE
Sheet metal on wooden battens or omega metal profiles.
PITCH SLOPE
≥ 21.5% (≥ 12°)
FORMATS
Spacing:
240 - 420 mm
Max length:
5 m
THICKNESS
0.7 - 0.8 - 1.0 mm