Our offices will be closed 4th to 27th of August

Seam roofing system

Seam roofing system

Seaming allows for the joining of profiled slabs via superimposing and folding of their edges.

The slabs are fastened to the substructure by using concealed clips.

It is also possible to apply double seaming for sloping surfaces ≥ 5% or angular seaming for roof slopes ≥ 47% .

The standard seam height is 25 mm.

TYPES OF SUBSTRUCTURE

SEAM VENTILATED ROOF WITH WOODEN SUBSTRUCTURE

1. zintek® seam roof cladding

2. Fastening clips

3a. Acoustic insulation draining filament mat h. 8 mm

4. Grooved wooden planking on battens, ventilated gap

5. Breathable waterproof sheathing

6. Thermal-acoustic insulation layer

7a. Vapour barrier to be verified with special thermo-hygrometric evaluations

SEAM NON-VENTILATED ROOF WITH CEMENT WOOD PANELS SUBSTRUCTURE

1. zintek® seam slabs roof cladding

2. Fastening clips

3b. Acoustic insulation draining filament mat h. 14 mm

5. Breathable waterproof sheathing

6. Thermal-acoustic insulation layer

7b. Vapour barrier to be verified with special thermo-hygrometric evaluations

8. High density cement wood panels, resistant against insects and termites (fire reaction Class A2)

TETTO VENTILATO CON SUPPORTO DI POSA IN LAMIERA (INCOMBUSTIBILE)

1. zintek® seam slabs roof cladding

2. Fastening clips

3b. Acoustic insulation draining filament mat h. 14 mm

5. Breathable waterproof sheathing

6. Thermal-acoustic insulation layer

7a. Vapour barrier / vapor barrier to be verified with special thermo-hygrometric evaluations

9. Sheet metal

10. Corrugated sheet metal supporting structure and ventilated gap

11. Metal support profiles

SEAM TYPES

25 mm ANGULAR SEAM

for sloping surfaces ≥ 25° (46%)

38 mm ANGULAR SEAM

for sloping surfaces ≥ 25° (46%)

25 mm DOUBLE SEAM

for sloping surfaces ≥ 7° (12%), specific seals are installed in the seam or a waterproof layer is inserted.

38 mm DOUBLE SEAM

for ≥ 3° (5%) sloping surfaces

EXAMPLE OF INSTALLATION SCHEMES

CONTINUOUS JOINTLESS SEAM

UP TO A LENGTH OF 18 m WITH SLIDE CLIPS

CONTINUOUS SEAM

AND ALIGNED TRANSVERSAL JOINTS

CONTINUOUS SEAM

AND STAGGERED TRANSVERSAL JOINTS

DOUBLE SEAM ASSEMBLY PROCESS

Step - 1

Installation of zintek® profiled slab H=25

Step - 2

Installation of sliding clip and fastening with screws

Step - 3

Installation of overlapping zintek® profiled slab

Step - 4

Double seam

TECHNICAL SPECIFICATIONS

Utilizzo

USE

Roof cladding and coating

Piano di posa

"SUBSTRUCTURE

Raw spruce wood planking, cement wood panels, sheet metal, OSB CLASS 3 wooden panels

Pendenza di Falda

PITCH SLOPE

≥ 3* (5%)

Formati

FORMATS

Standard width:
480 mm
Other available widths:
260, 300, 430, 500 mm

ico-Spessori

THICKNESS

0.7 mm

TYPES OF CLADDING SYSTEM